Build
Pick a lot. One Stair runs the seven checks, chooses the forms that fit, and returns a scheme a builder can price and a planner can read at a pre-application meeting. This is a sample of what a Build returns.
The lot
- Lot
- 18.0 × 36.0 m, 648 m²
- Municipality
- Surrey
- Plan
- Surrey 2050, Low-Rise
- Transit
- Tier 3, 400 to 800 m from Surrey Central
- Zoning today
- R3, two dwellings
- Envelope
- 12.0 × 24.0 m, 3.0 m sides, 6.0 m front and rear
- Forms that fit
- F18 Single, two schemes
The seven checks
- OCP designation: Low-Rise, apartments expectedPass
- Transit tier 3: 8 storeys and 3.0 FAR must be allowed, no resident parkingPass
- Zoning: R3 allows two homes; MR7 asks for 36 m frontage. Site-specific zone neededRezone
- Lot geometry: 18.0 m wide, 36.0 m deep, 100% of its rectangle, interior lotPass
- Setbacks and envelope: 12.0 × 24.0 m plate, four homes a floorPass
- Building Code 3.2.10: six storeys, sprinklered, 1.5 m stair, travel distance metPass
- Fire service and servicing: Surrey Fire capability under Note A-3.2.10, water supplyConfirm
Two schemes were predetermined for this lot. Pick one below.
Two schemes for this lot
23Homes
6Three-bed
2.61FAR
9Stalls
1,694 m²Gross
85%Efficiency
+18.5 mRoof
| Statistics | |
|---|---|
| Lot | 648 m² |
| Footprint, levels 2 to 6 | 288.0 m² · 44.4% |
| Gross floor area | 1,694.4 m² |
| Usable, net | 1,445.2 m² |
| FAR | 2.61 of 3.0 allowed |
| Homes: studio · 1 · 2 · 3 bed | 1 · 5 · 11 · 6 |
| Stalls, required · provided | 0 · 9 |
| Long-term bikes | 28 |
| Roof deck · required | 112 · 92 m² |
| Excavation | P1 540 m² plus ramp |
| Code checklist, BCBC 3.2.10 | |
|---|---|
| Storeys above grade, 6 maximum | 6 |
| Sprinklered throughout, NFPA 13 | Yes |
| Exit stair width, 1.5 m minimum | 1.5 m |
| Stair pressurized or vestibuled | Vestibule |
| Travel distance to the stair | Within limit |
| Occupant load per storey | 16 |
| Suite entry doors, 3.2.10.4 | Rated, self-closing |
| Emergency power | Generator |
| Fire department capability, Note A-3.2.10 | Confirm with Surrey Fire |
22Homes
6Three-bed
2.63FAR
13Stalls
1,706 m²Gross
80%Efficiency
+19.0 mRoof
| Statistics | |
|---|---|
| Lot | 648 m² |
| Gross floor area | 1,706 m² |
| Usable, net | 1,365 m² |
| FAR | 2.63 of 3.0 allowed |
| Homes: studio · 1 · 2 · 3 bed | 5 · 5 · 6 · 6 |
| Stalls, required · provided | 0 · 13 |
| Stalls per home | 0.59 |
| Roof deck | 135 m² |
| Excavation | P1 540 m² plus ramp |
| Code checklist, BCBC 3.2.10 | |
|---|---|
| Storeys above grade, 6 maximum | 6 |
| Sprinklered throughout, NFPA 13 | Yes |
| Exit stair width, 1.5 m minimum | 1.5 m |
| Stair pressurized or vestibuled | Pressurized |
| Travel distance to the stair | Within limit |
| Occupant load per storey | 16 |
| Suite entry doors, 3.2.10.4 | Rated, self-closing |
| Emergency power | Generator |
| Fire department capability, Note A-3.2.10 | Confirm with Surrey Fire |
What a Build
returns
Site planTo scale on the real parcel, with setbacks, neighbours, the ramp and the nearest station.
Floor plansParkade, ground, typical and roof, with every home labelled and measured.
Section and elevationThrough the core and from the street, with levels and the height limit.
StatisticsFloor area, FAR against the plan, unit mix, parking, bikes, amenity, excavation.
Code checklistEvery 3.2.10 condition with the clause behind it, and what is left to confirm.
Pre-application summaryOne page a planner can read: the plan, the tier, the zone, the ask.
Schematic only
A Build is a schematic design and a test fit, not a permit set. Every scheme must be verified and sealed by a registered architect before it is relied on, priced or submitted. Stall and aisle dimensions, ramp grades, setbacks, servicing and the BCBC 3.2.10 conditions all need confirming for the specific site. Form Architects can carry any Build into a tailored scheme.
Find a lot on the mapOr ask Form Architects for a Build: [email protected]